Most measurements taken during UPS maintenance show electrical values (voltage, current, etc.).
However, there are some critical risks that are revealed not by measuring instruments, but by heat .
That's why thermal camera testing is an indispensable part of UPS maintenance.
Short and to the point:
In UPS maintenance where thermal camera testing is not performed, unseen risks go unnoticed.
What is a Thermal Camera Test?
Thermal camera testing allows you to observe the temperature distribution at the UPS, batteries, and connection points.
-
Overheating points
-
Loose or oxidized connections
-
Unbalanced batteries
-
Overload and cooling problems
It allows detection without being visible to the naked eye .
📌 In electrical systems , heat is the earliest indicator of an impending malfunction .
Why is thermal testing critical in UPS maintenance?
1️⃣ It detects loose connections early.
If a terminal is loose:
-
It may appear "normal" on a multimeter.
-
It appears as a hot spot on the thermal camera.
👉 This hotspot is coming up:
-
Spark
-
Melting
-
Fire
It means risk.
2️⃣ It shows battery problems before they swell up 🔋
Weak or unstable batteries:
-
It heats up more than others under load.
-
It's noticeable even before swelling occurs.
📌 So:
-
Before the battery explodes
-
UPS fails during outage
Change is planned.
3️⃣ It reveals excessive load and uneven distribution.
If the UPS is operating near its capacity:
-
Inverter
-
Output terminals
-
Cableways
It gets warmer than usual.
👉 Thermal image,
It provides a clear answer to the question , "Is the UPS small?"
4️⃣ Shows Fan and Cooling Problems 🌬️
The fan might be running, but:
-
Insufficient airflow.
-
There may be a dust blockage.
Thermal Camera:
-
Areas that cannot be cooled
-
Heat accumulation
It makes it clear.
5️⃣ Detects Fire Risks in Advance 🔥
Most fires are caused by electrical sources.
-
Overheating
-
Loose contact
It arises because of...
📌 Thanks to thermal testing:
The risk is identified before a fire breaks out.
Which systems require thermal camera testing?
Especially:
-
🖥️ Server rooms
-
🎥 CCTV systems
-
🏥 Hospitals
-
🏭 Industrial facilities
-
🏢 Large offices
In these areas, a UPS failure is not a minor problem .
How often should thermal camera tests be performed?
-
🗓️ Office / small business → Once a year
-
🗓️ CCTV & high-voltage UPS → Once every 6 months
-
🗓️ Server / critical infrastructure → Every 3-6 months
📌 If the battery is older than 2 years, the interval between uses should be shortened .
Why is electrical measurement alone insufficient?
Because:
-
The voltage may be normal.
-
The current may be normal.
But:
-
The temperature is rising.
👉 Electrical faults often start as heat , then progress to a malfunction.
How do we perform thermal testing at cctvburada?
As cctvburada;
-
🔍 We scan the UPS, battery, and all connections with a thermal camera.
-
🌡️ We are marking abnormal temperatures.
-
📊 We create a risk report along with electrical measurements.
-
🔧 We suggest on-site improvements if needed.
We don't just measure maintenance, we observe it.
📞 Does your UPS maintenance include thermal testing?
If you're unsure, it probably doesn't include it.
👉 Free consultation
👉 UPS maintenance service including thermal camera