What Do Low Current Systems Include?

Zayıf Akım Sistemleri Neleri Kapsar?
System Aim
Fire Alarm System Early warning and evacuation
CCTV Camera System Security monitoring and recording
Intercom and Video Intercom Communication between departments and security
Access Control (Card Entry) Preventing unauthorized access
TV/SAT and IPTV Systems Common antenna, central broadcast
Data & Telephone Infrastructure Internet and telephone line distribution
UPS (Uninterruptible Power System) Uninterrupted power for critical systems
Lighting Automation Energy efficiency in common areas
Parking Guidance / LPR License plate recognition and parking access system
Bell – Announcement System Announcement, guidance and warning voice
Fiber Infrastructure / Structured Cabling The core of all communication systems

Things to Consider in Project Design

Compliance with Appropriate Regulations

Compliance with TSE, EN54, EPDK, Transportation and BTK standards.

Especially for the fire alarm system, the Regulation on the Protection of Buildings from Fire should be taken as a basis.

Modular and Expandable Structure

Each system should be designed with flexibility to allow for future additions (especially fiber, CCTV, IPTV).

Central System Use

Security systems (camera, card access, fire, etc.) should be monitored through a single monitoring and management center .

Distribution of Infrastructure to Apartments

To each apartment:

1 or more data sockets

telephone line

Central broadcast line (TV/SAT)

Intercom line

The project should be designed to include an optional home automation module.

Grounding and Cable Channel Management

Weak current cables should be laid on routes completely separate from those for high currents.

High quality EMC shielded cables should be preferred especially in systems such as CCTV and intercom.

Energy Efficiency & Automation

Sensor systems for common area lighting.

Compatibility with smart meter infrastructure.

Data Center and System Room

A suitable cooled system room should be planned for CCTV recorders, access control servers and other equipment.

19” rack cabinet , redundant UPS supply, and fire detection systems should be in this room.


What Should Be Included in Project Delivery?

Floor-based system drawings on architectural layout plans (separately for each low-current system)

Riser diagram (vertical column diagrams)

List of symbols and their explanations

Cable metering lists

Material list and brand/model recommendations

Application and installation details

Testing and commissioning procedures